Interior nonstructural walls and partitions
|
|
|
|
|
1 |
--- Light frame ≤ 9ft (2.74m) in height |
1.0 |
1.0 |
1.5 |
1.5 |
2 |
--- Light frame > 9ft (2.74m) in height |
1.4 |
1.4 |
1.5 |
2.0 |
3 |
--- Reinforced Masonry |
1.0 |
1.0 |
1.5 |
1.5 |
4 |
--- All other walls and partitions |
2.0 |
2.8 |
1.5 |
1.5 |
|
Cantilever elements (unbraced or braced to structure below its center of mass)
|
|
|
|
|
5 |
--- Parapets and cantilever interior nonstructural walls |
1.8 |
2.2 |
1.5 |
1.75 |
6 |
--- Chimneys where laterally braced or supported by the structural frame |
1.8 |
2.2 |
1.5 |
1.75 |
|
Cantilever elements (braced to structural frame above its center of mass)
|
|
|
|
|
7 |
--- Parapets |
1.0 |
1.0 |
1.5 |
1.5 |
8 |
--- Chimneys |
1.0 |
1.0 |
1.5 |
1.5 |
9 |
--- Exterior nonstructural walls |
1.0 |
1.0 |
1.5 |
1.5 |
|
Exterior nonstructural wall elements and connections
|
|
|
|
|
10 |
--- Wall element |
1.0 |
1.0 |
1.5 |
1.5 |
11 |
--- Body of wall panel connections |
1.0 |
1.0 |
1.5 |
1.5 |
12 |
--- Fasteners of the connecting system |
2.2 |
2.8 |
1.5 |
1.0 |
|
Veneer
|
|
|
|
|
13 |
--- Limited deformability elements and attachments |
1.0 |
1.0 |
1.5 |
1.5 |
14 |
--- Low deformability elements and attachments |
1.0 |
1.0 |
1.5 |
1.5 |
|
Penthouses (except where framed by an extension of the building frame)
|
|
|
|
|
15 |
--- Seismic Force-Resisting Systems with R≥6 |
N/A |
1.4 |
2.0 |
2.0 |
16 |
--- Seismic Force-Resisting Systems with 6>R≥4 |
N/A |
2.2 |
2.0 |
1.75 |
17 |
--- Seismic Force-Resisting Systems with R<4 |
N/A |
2.8 |
2.0 |
1.5 |
18 |
--- Other Systems |
N/A |
2.8 |
1.5 |
1.5 |
|
Ceilings
|
|
|
|
|
19 |
--- All |
1.0 |
1.0 |
1.5 |
1.5 |
|
Cabinets
|
|
|
|
|
20 |
--- Permanent floor-supported storage cabinets more than 6 ft (1,829 mm) tall, including contents |
1.0 |
1.0 |
1.5 |
1.5 |
21 |
--- Permanent floor-supported library shelving, book stacks, and bookshelves more than 6 ft (1,829 mm) tall, including contents |
1.0 |
1.0 |
1.5 |
1.5 |
22 |
Laboratory equipment
|
1.0 |
1.0 |
1.5 |
1.5 |
|
Access Floors
|
|
|
|
|
23 |
--- Special access floors (designed in accordance with Section 13.5.7.2) |
1.0 |
1.0 |
1.5 |
1.5 |
24 |
--- All other |
2.2 |
2.8 |
1.5 |
1.5 |
25 |
Appendages and ornamentations
|
1.8 |
2.2 |
1.5 |
1.75 |
26 |
Signs and Billboards
|
1.8 |
2.2 |
1.5 |
1.75 |
27 |
Other rigid components
|
1.0 |
1.0 |
1.5 |
1.5 |
|
Other flexible components
|
|
|
|
|
28 |
--- High-deformability elements and attachments |
1.4 |
1.4 |
1.5 |
2.0 |
29 |
--- Limited-deformability elements and attachments |
1.8 |
2.2 |
1.5 |
1.75 |
30 |
--- Low-deformability elements and attachments |
2.2 |
2.8 |
1.5 |
1.5 |
31 |
Egress stairways not part of the building seismic force-resisting system
|
1.0 |
1.0 |
1.5 |
1.5 |
32 |
Egress stairs and ramp fasteners and attachments
|
1.8 |
2.2 |
1.5 |
1.75 |